Gun Type
TN418 Series_3 Key
Specifications
〈TN418LC〉
〈TN418LC〉
- Measurement Range: -60~500°C (-76~932°F)
- Full Range Accuracy:
Tobj=-33~500°C: ±2% of reading or 2°C(4°F) whichever is greater
- Distance : Spot: 12 : 1
〈TN418LD〉
- Measurement Range: -60~625°C (-76~1157°F)
- Full Range Accuracy:
≥0°C: ±2% of reading or 2°C(4°F) whichever is greater
<0°C: ±(2°C + 0.05/°C)°C
- Distance : Spot: 16 : 1
- Thermocouple Probe: Small Socket, K type, 12 minutes auto power off
- Measurement Range*: -64~1400°C(-83.2~1999°F)
- Probe Accuracy: ±1% of reading or 1°C(1.8°F) whichever is greater(Test under Tamb=23±6°C)
Introduction
-
Feature
- Select operating modes and adjust parameters easily
- Built-in jack support and K-type TC probe with "mini-style" connector
- Dual Beam Laser sight <TN418LD(E)Z only>
- With White LED Flashlight (optional)
- Various Measurement Range & DS Ratio optional
- With Relative Humidity <TN418LCR>
Built-in Socket
LED Flashlight
(optional)Relative Humidity
<TN418LCR>Color Bar Display
( Model with G ) -
Applications
Automation
Electric Power
HACCP
Industry
HVAC
Laboratory
-
TN418LA TN418LB TN418L9 TN418LC TN418LD Measurement Range -60~760°C(-76~1400°F) -60~500°C(-76~932°F) -60~625°C(-76~1157°F) Full Range Accuracy Tobj= -33~760°C:
±2% of reading or 2°C(4°F)
whichever is greaterTobj= -33~500°C:
±2% of reading or 2°C(4°F)
whichever is greater≥0°C : ±2% of reading or
2°C(4°F)whichever is greater
<0°C : ±(2°C+0.05/°C)°CDistance : Spot 20:1 30:1 12:1 12:1 16:1 Thermocouple Probe Small Socket, K type, 12 minutes
auto power offMeasurement Range* -64~1400°C(-83.2~1999°F) Probe Accuracy ±1% of reading or 1°C(1.8°F) whichever
is greater(Test under Tamb=23±6°C)